Handheld Power Control, 25ft (7.6m) coiled cableīNC to Microdot.

Rack Adapter: mounts two 5¼" instruments in 19" rackĬABLE, COILED, 3M (10FT), FOR HANDHELP POWER CONTROLLER Rack Adapter - mounts two 5-1/4" instruments in 19" rack
#10 FOOT QUARTZCRYSTAL FULL#
RACK EXTENDER, 3.5" FULL, HARDWARE TO MOUNT ONE FTC-2800 OR FTM-2400 INSTRUMENT IN A 19" RACKģ-1/2" Full Rack Extender: For FTC-2800 orįTM-2400 Hardware to mount one instrument in a 19" rack.ģ-1/2" HALF RACK ADAPTER, FOR FTC-2800 OR FTM-2400 HARDWARE TO MOUNT TWO INSTRUMENTS IN A 19" RACKģ-1/2" Half Rack Adapter: For FTC-2800 orįTM-2400 Hardware to mount two instruments in a 19" rack

Rack Extender: mounts one 5¼" instrument in 19" rack RACK EXTENDER, MOUNTS ONE 5-1/4" INSTRUMENT IN 19" RACK If a replacement Is required, please view the Accessories table below. This is usually included in the oscillator package. The sensor input BNC cable connects the other end of the oscillator to the FTM-2400 monitor. If a replacement is required, please view the Accessories table below. The active oscillator is a standard oscillator for in-situ thin film deposition rate measurements. This is usually included in the oscillator kit.

The short BNC cable connects the atmospheric side of the flange to the oscillator. Please view the QCM Crystal page for further details. These feedthroughs come standard with either a 1" bolt or DN40CF flange.Ĭrystals, whether Gold, Silver, or Alloy, are all dependent on the process. Most QCM sensors are available with or without a feedthrough, where coming with a feedthrough is the most common. The In-vacuum cable is generally supplied with the QCM Sensor. Please note that the STM-2 does not work with shuttered sensors. For common applications, a Front Load Sensor or Cool Drawer Sensor with a single crystal holder may be appropriate. The type of necessary sensor is based on the application. If you do not see an item that you need, please contact your local KJLC Sales Representative. Note: Below you will find common components needed to build a complete package. Stored Films: 99 Analog Outputs: Two 0 to 5 VDC, rate & thickness Digital Inputs/Outputs: Four inputs, four relay outputs Communications Interface: Standard: RS-232, Optional: USB or Ethernet QCM Sensor Inputs: Standard: 2, optional: 4 Measurement Frequency Range: Adjustable, 1.0 MHz minimum - 6.5 MHz maximum Frequency Resolution (1): ± 0.03 Hz Thickness & Rate Resolution/Measurement (2): ± 0.037 Å Measurement Interval: 0.10 to 2.0 s (adjustable) Measurement Filter: 1 to 20 readings QCM Sensor Inputs: Standard: 2, optional: 4 Measurement Frequency Range: Adjustable, 1.0 MHz minimum - 6.5 MHz maximum Frequency Resolution (1): ± 0.30 Hz Thickness & Rate Resolution/Measurement (2): ± 0.37 Å Measurement Interval: 0.10 to 2.0 s (adjustable) Measurement Filter: 1 to 20 readings